In 1967, the Los Angeles Fire Department (LAFD) established a collection of rules governing the operation of fire protection equipment and systems in the city. These rules became known as Chief’s Regulation No. 4—the name refers to the fire chief’s role in creating and enforcing these guidelines. Under Chief’s Regulation No. 4, all fire protection equipment and systems across Los Angeles must undergo testing at scheduled intervals to ensure acceptable performance.

Originally, the Chief’s Regulation No. 4 called for all testing to be witnessed by the fire department fire station or fire prevention unit personnel. This requirement proved to be difficult to comply with, however, due to the strain on LAFD resources. In response, Chief’s Regulation 4 codes were amended in the 1980s to authorize certain qualified individuals, called “certified testers,” to perform tests of fire protection equipment.

Fraker Fire Protection Inc. employs a team of technicians who are qualified to perform Chief’s Regulation No. 4 tests.

Regulation 4 Testing Intervals

Under Chief’s Regulation 4 codes, certain types of fire prevention and fire suppression systems and equipment must be tested annually, while sp[rinkler and standpipe systems require testing every five years.

Fire protection devices, equipment, and systems that must be tested annually include the following:

  • Fire Alarm
  • Automatic Elevators (Phases I & II)
  • Central Station Signaling Systems
  • Emergency & Standby Power Systems
  • Emergency Voice Alarm Signaling Systems
  • Fire Department Communication Systems
  • Fire Escape Assemblies
  • Fire Pumps
  • Gas Detection Systems
  • Private Fire Hydrants
  • Smoke Management Systems
  • Fire Door Assemblies

Fire protection devices, equipment, and systems that must be tested every five years include the following:

  • Fire Sprinkler Systems
  • Class I Standpipe Systems
  • Class II & III Standpipe Systems
  • Combined Standpipe Systems

Our Range of Expertise

The technicians at Fraker Fire Protection Inc. are certified to perform Regulation 4 testing on these types of fire protection equipment:

  • Automatic Closing Fire Assemblies
  • Automatic Sprinkler Systems
  • Basic Fire Alarm Systems Only
  • Basic and Complex Fire Alarm Systems
  • Central Stations
  • Elevator Recall
  • Emergency Generator and Battery Systems
  • Fire Escape Assemblies
  • Fire Pumps
  • Mechanical Smoke-Proof Enclosures
  • Pressurized Stairshafts
  • Smoke Evacuation

We provide Regulation 4 testing services to clients in Los Angeles County, Ventura County, Orange County, and the Inland Empire. To schedule a test, call us toll-free at (866) 560-3473 or contact us online.